Rated shop
biocypep
Lab reports, prices and shop information with their sources.
- Products counted
- 7
- Measurement fields recorded
- 27/2896 %
- Shop information as of
At a glance
The evidence at a glance
7 products currently contribute to the rating. It is based on the recorded lab reports and does not establish facts about every batch or a product's safety.
- Location listed by the shop
- Cyprus
- Ships from
- Not stated
- Evidence gaps
- 1 missing measurement or documentation fields
Derived from the recorded information. This does not constitute an additional source check.
RATING
How it is made up
The segments show calculated category points. Select one to open the counted reports; deductions and missing measurements are explained below.
- NAD+ (Liquilabs LYO-0963): the report states a 1000 mg sample, 596 mg were measured. The shop sells the product as 500 mg and links this report to it. Report and product do not match.
- Note: Review status 25 October 2026: All 8 published PDFs come from Liquilabs, all published on 23 September 2026. Every verification link leads to the laboratory server (base.liquilabs.cz) and returns the same results. The shop copies show "Cyprus" in the client field where the laboratory version shows a personal name. For NAD+ the report states 1000 mg while the shop COA page states 500 mg. We do not know Liquilabs well enough yet, so we are still unsure about this laboratory. Until our review is complete, its reports count provisionally. This note does not trigger an additional deduction.
- Products counted
- 7
- Measurements recorded
- 27 of 28 (96%)
- Confidence
- Medium
- Calculated on
- 25 Oct 2026
- Methodology
- 1.1
Measurement fields cover purity, content, identity and endotoxins in counted reports. Recorded does not mean passed. The same data and calculation date produce the same rating.
MethodologyEvidence in context
What the records show
Derived from the recorded data. The date of the shop information is not recorded. This summary does not constitute an additional source check.
7 products are currently included in the rating. One report counts per product.
What is recorded
The dataset contains 8 reports for 7 products.
Newest counted report: . The report date is not the date of a renewed source check.
Reports and original sourcesWhat remains open
Not consistently recorded in the counted reports:
- Purity measurementmissing in 1 of 7
Documented notices 2
- Review status 25 October 2026: All 8 published PDFs come from Liquilabs, all published on 23 September 2026. Every verification link leads to the laboratory server (base.liquilabs.cz) and returns the same results. The shop copies show "Cyprus" in the client field where the laboratory version shows a personal name. For NAD+ the report states 1000 mg while the shop COA page states 500 mg. We do not know Liquilabs well enough yet, so we are still unsure about this laboratory. Until our review is complete, its reports count provisionally.
- NAD+ (Liquilabs LYO-0963): the report states a 1000 mg sample, 596 mg were measured. The shop sells the product as 500 mg and links this report to it. Report and product do not match.
Shop information and its sources · Reports and related notices
This context applies to the recorded documents. A report describes the tested sample; it does not establish facts about all batches, safety or efficacy. The rating is not a purchase recommendation. Understand the scope
Lab reports
84e4b21d0fc684711b040058c489a7318- Report found
- Lab: Liquilabs
- Code entered
- Original confirmed with the lab
8 recorded reports. The calculation shows which reports count and why.
See all measurements: scroll the table horizontally.
| Product | Content | Purity | LC-MS | Endotoxins | Lab and date | Points |
|---|---|---|---|---|---|---|
| CJC-1295+Ipamorelin 5 mg / 5 mg | +9.4 %, +11.8 % | not recorded | confirmed | 0.130 EU/Vial | Liquilabs, 23 Sept 2026Code 4e4b21d0fc684711b040058c489a7318Report an error | 5.36 of 7.86-2.50 purity |
| NAD+ 1000 mg | -40.4 % | 97.100 % | confirmed | < 1.000 EU/Vial | Liquilabs, 23 Sept 2026Code 7ae4038bb18949daa887980d6174aadcReport an error | 4.73 of 7.86-0.63 purity, -2.50 content |
| PT-141 10 mg | +5.9 % | 99.700 % | confirmed | 2.350 EU/Vial | Liquilabs, 23 Sept 2026Code e921ab15ea964a6a8d77932635a67e3fReport an error | 7.86 of 7.86full points |
| SS-31 50 mg | +18.4 % | 99.800 % | confirmed | 0.150 EU/Vial | Liquilabs, 23 Sept 2026Code ff5244fc6eb34a478ef7d74f5809b826Report an error | 7.86 of 7.86full points |
| SS-31 10 mg | -20.4 % | 99.500 % | confirmed | 4.550 EU/Vial | Liquilabs, 23 Sept 2026Code fa8cbdb7143648278ed1457d731d13bfReport an error | not countedlab does not count |
| Snap-8 10 mg | -20.4 % | 99.600 % | confirmed | 4.660 EU/Vial | Liquilabs, 23 Sept 2026Code 7cb4d95cb4ff4d3d96ecfa5242d344b7Report an error | 5.36 of 7.86-2.50 content |
| TB-500 10 mg | -22.8 % | 99.000 % | confirmed | 2.780 EU/Vial | Liquilabs, 23 Sept 2026Code 52de45560328484ba6f103b22e76d6b2Report an error | 5.36 of 7.86-2.50 content |
| Tesamorelin 10 mg | -3.6 % | 99.000 % | confirmed | 0.100 EU/Vial | Liquilabs, 23 Sept 2026Code 1ffec0672a244871a9b5384cb0233670Report an error | 7.86 of 7.86full points |
Understand the measurements
How pure is the sample?
Separated peaks reveal components in a chromatogram.
A purity figure describes the result under the method used. It establishes neither the amount present nor sterility.
Schematic illustration, not this shop’s measurements.
How much is present?
The measured amount is compared with the declared amount.
Quantification requires suitable calibration. High purity does not automatically mean the declared amount is present. For blends, total amount and component ratio are separate questions.
Schematic illustration, not this shop’s measurements.
Does the identity match?
Mass signals are compared with the expected compound.
LC-MS provides molecular-mass evidence. Further structural or sequence confirmation may require additional analyses. We record only explicitly documented findings.
Schematic illustration, not this shop’s measurements.
Are bacterial endotoxins detectable?
Endotoxins are components of certain bacteria. They can remain after the bacteria die. A separate test checks the sample for them.
The diagram illustrates a quantitative colour assay: standards with known amounts help interpret the sample signal. Without a test, this question remains open. A low endotoxin value does not establish sterility. Consult the original report for units and detection limits.
Schematic illustration, not this shop’s measurements.
A closer look
Reading the evidence
Does one lab report cover every batch?
A report documents the tested sample. Product, amount and batch number must match the record. A result cannot be extended to other batches or the entire range. The shop rating counts one report per product; this does not automatically verify the remaining stock.
Batches and documentationDoes a missing entry mean a measured value of zero?
No. “Not recorded” or “not measured” remains unknown. The methodology awards no points for it, but we do not fill in a measured value of zero. If the entire shop lacks a calculable basis, no rating is shown. An actual displayed score of 0 points is distinct from that; documented warnings remain visible.
Rating eligibilityWhy can a rating fall over time?
Each counted report earns 10 freshness points up to and including 90 days, 6 points up to 180 days, then 3. The mean of these values determines the shop’s freshness points. Reports older than 365 days no longer count. The next recalculation can therefore lower a rating without new measurements. Without an eligible report, a regular rating cannot be calculated; documented warnings remain separately identified.
Freshness in the methodologyPrices
We have not found prices for the products in our price comparison here yet.
Prices without shipping, as of . The price in the shop is binding.
Go to the price comparisonFacts
- Company (legal notice)
- Statwal Ltd.Report an error
- Based in
- CyprusReport an error
- Website
- biocypep.eu Report an error
- Ships from
- Not statedReport an error
- Shipping cost to Germany
- Not statedReport an error
- Payment
- Report an errorCard, Crypto · shop claim
- Price level
- Too few comparable pricesReport an error
- Own lab reports
- Yes · Liquilabs Report an error
- Trustpilot
- No profileReport an error
As of . The facts come from the shop's website and Trustpilot. We checked negative details such as removed profiles or invalid tax numbers ourselves.
Contact channels
1 channel listed on the shop's website
We only pass on what the shop lists itself. As of 20 Oct 2026.
History
History starts after the initial reviews
Once the initial review of every provider is complete, tracking begins from a new baseline.
This page will then show only documented changes concerning biocypep, such as changes to lab reports, prices or its rating.
Corrections and responses
Is a detail incorrect? Send us a sourced correction or a response about this shop.
Report an error about this shop Response from the shop
Responses and appeals